ADAPT-Floor Pro/MAT FAQ and Video added

The following video and FAQ have been added for ADAPT-Floor Pro/MA

Builder 2010 Mesh Reiforcement Placement

How does ADAPT-Builder set the depth of mesh reinforcement or other base rebar when a model contains more than one slab region of different depths?
The cover of reinforcement is taken relative to the first slab input into the model.  Any mesh reinforcement assigned will be located in depth relative to the dimensions of this slab.  If mesh reinforcement is required at different depths, assign individual meshes to different slab regions and modify the cover to the proper value.  Note that negative covers are acceptable to shift a mesh downward.  See the video “Bulder 1010 Mesh Reinforcement Placement” on the ADAPT-Floor Pro/MAT video page for an example.

Add to FacebookAdd to DiggAdd to Del.icio.usAdd to StumbleuponAdd to RedditAdd to BlinklistAdd to TwitterAdd to TechnoratiAdd to Yahoo BuzzAdd to Newsvine